Verified product catalogue
Choose a product
56 products match
AWV-000635
Ductile Iron Butterfly Valve – Pneumatically Actuated
Ductile Iron · Wafer · PN10/16, ANSI 150, PN10
Price: On Application
AWV-000641
Ductile Iron Butterfly Valve – Pneumatically Actuated
Ductile Iron · Wafer · PN6/10, ANSI 150, PN16, PN10
Price: On Application
AWV-000648
Stainless Steel Ball Valve – Electrically Actuated
Stainless Steel · BSPP · 10 Bar
Price: On Application
AWV-000649
Stainless Steel Ball Valve – Electrically Actuated
Stainless Steel · BSPP · PN63
Price: On Application
AWV-000667
Ductile Iron Butterfly Valve – Electrically Actuated
Ductile Iron · Lugged & Tapped · PN10/16, PN10
Price: On Application
AWV-000668
Ductile Iron Butterfly Valve – Electrically Actuated
Ductile Iron · Lugged & Tapped · PN10/16, PN10
Price: On Application
AWV-000669
Ductile Iron Butterfly Valve – Electrically Actuated
Ductile Iron · Wafer · PN10/16, ANSI 150, PN10
Price: On Application
AWV-000670
Ductile Iron Butterfly Valve – Electrically Actuated
Ductile Iron · Wafer · PN10/16, ANSI 150, PN10
Price: On Application
AWV-000671
Carbon Steel High Performance Butterfly Valve – Electrically Actuated
Carbon Steel · Wafer · PN10/16, ANSI 150, PN25
Price: On Application
AWV-000672
Carbon Steel High Performance Butterfly Valve – Electrically Actuated
Carbon Steel · Lugged & Tapped · PN16/25, PN16, PN25
Price: On Application
AWV-000673
Stainless Steel Butterfly Valve – Electrically Actuated
Stainless Steel · Wafer · PN6/10, ANSI 150, PN16, PN10
Price: On Application
AWV-000674
Ductile Iron Butterfly Valve – Electrically Actuated
Ductile Iron · Lugged & Tapped · ANSI 150, PN16
Price: On Application
AWV-000675
Ductile Iron Butterfly Valve – Electrically Actuated
Ductile Iron · Lugged & Tapped · PN10/16, PN16, PN10
Price: On Application
AWV-000676
Ductile Iron Butterfly Valve – Electrically Actuated
Ductile Iron · Wafer · PN6/10, ANSI 150, PN16, PN10
Price: On Application
AWV-000677
Stainless Steel 3 Way Ball Valve – Electrically Actuated
Stainless Steel · PN16 · PN16
Price: On Application
AWV-000678
Stainless Steel 3 Way Ball Valve – Electrically Actuated
Stainless Steel · PN16 · PN16
Price: On Application
AWV-000679
Stainless Steel Ball Valve – Electrically Actuated
Stainless Steel · ANSI 150 · ANSI 150, PN40, PN16
Price: On Application
AWV-000680
Stainless Steel Ball Valve – Electrically Actuated
Stainless Steel · PN16 · PN16, PN40
Price: On Application
AWV-000681
Stainless Steel Ball Valve – Electrically Actuated
Stainless Steel · BSPT · PN63
Price: On Application
AWV-000682
Stainless Steel Ball Valve – Electrically Actuated
Stainless Steel · BSPP · 10 Bar
Price: On Application
AWV-000683
Stainless Steel Ball Valve – Electrically Actuated
Stainless Steel · Clamp · PN63, PN55, PN40
Price: On Application
Technical overview and selection guidance
This guide explains electric actuator selection in practical terms and shows where the concept affects valve or actuator selection.
Why it matters
Valve decisions often fail when a label, nominal rating or catalogue headline is treated as a complete specification. Use the concept here to ask better questions, then verify the answer against the governing standard and current manufacturer documentation.
Engineering workflow
- Define the process case, including normal and worst credible conditions.
- Use consistent units and distinguish operating data from design data.
- Identify the product variables that affect the result.
- Check assumptions against a current datasheet, calculation method or standard.
- Record the basis of selection for review and future maintenance.
Common mistakes
- Mixing gauge and absolute pressure, or nominal and actual dimensions.
- Assuming a standard name guarantees every construction detail.
- Ignoring temperature derating, fluid properties or transient conditions.
- Using approximate guidance as a final certified calculation.
Questions to carry into an enquiry
- Which values are measured, calculated or assumed?
- Which operating case controls the selection?
- What evidence is required—datasheet, certificate, test report or calculation?
- What happens if the valve fails open, closed or in place?