Pressure Relief Valve Sizing and Set Pressure Selection: API 520/521 Methodology for Process Engineers

Quick Summary:

  • Pressure relief valve sizing per API 520 Part I uses different calculation methodologies depending on the relieving fluid phase and the nature of the overpressure scenario — the single largest sizing error is applying a vapour sizing equation to a two-phase or liquid relieving scenario, which results in a severely undersized valve that cannot prevent vessel overpressure in the design contingency.
  • Set pressure selection must account for the accumulation allowance permitted by ASME Section VIII and API 520 — for a single relief valve protecting a vessel operating at the maximum allowable working pressure (MAWP), the set pressure equals the MAWP and the valve must relieve at or before 10% above MAWP (110% MAWP is the maximum allowable accumulation for a single valve in a non-fire case); this distinction between set pressure and accumulated pressure is routinely confused.
  • API 521 provides the contingency analysis methodology — the identification of all credible overpressure scenarios, the determination of the governing (largest) relief load, and the basis for the relief system design — and is equally important as API 520; sizing a relief valve without a proper API 521 contingency analysis is specifying a relief valve without knowing whether it is for the right scenario.

The Purpose and Limits of Pressure Relief Valves

A pressure relief valve (PRV) — also called a safety relief valve (SRV) or, in gas-only service, a pressure safety valve (PSV) — is the last line of overpressure protection for a pressure vessel, piping system, or equipment item. When every other layer of overpressure protection has failed — the control valve has stuck open, the block valve has been left open in error, the utility supply has surged to abnormal pressure — the relief valve is the device that prevents the vessel from rupturing.

This is not a device you want to fail, and it is not a device you want to be undersized. An undersized relief valve in a fire case — where the vessel is being heated externally and the liquid inside is rapidly vapourising — allows vessel pressure to continue rising above the allowed accumulation level. If it reaches the test pressure and beyond, the vessel is at risk of catastrophic failure.

At the same time, an oversized relief valve introduces its own problems: chattering (the valve cycles open and closed rapidly when the relieving load is much lower than the valve capacity, because the actual system pressure drops significantly below set pressure once the valve opens, causing it to re-seat and then open again repeatedly, which causes rapid wear of the disc and seat, dramatically reducing valve life and reliability).

Correct sizing is therefore not a matter of erring on the side of bigger — it is a matter of matching the valve capacity to the actual relieving load with reasonable but not excessive margin.

API 520 and API 521: The Two Documents You Need Together

API 520 “Sizing, Selection, and Installation of Pressure-Relieving Devices” is published in two parts. Part I covers the sizing and selection methodology — the calculation procedures for determining the required orifice area for a given relieving load, set pressure, and fluid properties. Part II covers the installation requirements — the design of the inlet and outlet piping to the relief valve, the back-pressure effects, and the downstream collection system.

API 521 “Pressure-Relieving and Depressuring Systems” provides the contingency analysis methodology — the process of identifying all credible overpressure scenarios for a given equipment item, calculating the relief load for each scenario, and selecting the governing (highest load) scenario that determines the required valve capacity. API 521 also covers the design of the relief header system, knockout drums, flares, and other elements of the complete pressure relief system beyond the individual valve.

These two documents are inseparable. API 520 tells you how to size the valve for a given load. API 521 tells you what that load should be. Using API 520 without a proper API 521 contingency analysis means you may be sizing the valve for the wrong scenario entirely — and the relief valve, even if correctly sized for the assumed scenario, will not protect the vessel in the actual worst-case overpressure event.

Overpressure Contingency Analysis: API 521 Scenarios

API 521 identifies the following categories of overpressure scenarios that must be evaluated for any protected equipment item:

Blocked outlet: The most common governing scenario for vessels and heat exchangers. If all outlet isolation valves are closed (deliberately or by control failure) while the inlet continues to flow, the vessel pressure will rise at a rate determined by the inlet flow. The relief load is the maximum inlet flow rate at the maximum normal operating pressure.

Control valve failure: A control valve that fails open passes its maximum flow rate (Cv at full open times the square root of the available pressure differential) rather than the normal setpoint flow. For heat exchangers with steam or hot fluid on the shell side, a failed-open steam control valve can rapidly generate large vapour loads from the tube-side fluid, producing a relief load much larger than the blocked outlet case.

External fire: Fire exposure to a vessel containing liquid produces vapourisation of the liquid from the heat input. API 521 provides an empirical correlation for the heat input from a pool fire based on the vessel exposed surface area (with wetting factor correction for wetted surface vs total surface) and the latent heat of vaporisation of the liquid. The fire case relief load can be the governing case for large liquid storage vessels, particularly where the liquid has a relatively low latent heat of vaporisation (light hydrocarbons, LPG).

Thermal expansion: Liquid-filled systems (heat exchangers, long-distance liquid pipelines, jacketed vessels) that can be isolated on both sides while containing liquid are subject to pressure rise from thermal expansion if the liquid is heated. The relief valve in this case is small — the expansion volume of liquid per degree of temperature rise is small — but the relief scenario is frequently overlooked. Thermal relief valves in the 3/4 inch × 1 inch size range are the standard response to this scenario.

Utility failure: Loss of cooling water to a condenser causes condensate to accumulate in a distillation column, eventually flooding the column and causing column pressure to rise as the vapour cannot condense. Loss of instrument air may cause control valves to fail to their fail-safe position (fail-open on process supply, fail-closed on cooling), creating combined overpressure from multiple simultaneous events. API 521 requires that utility failure scenarios be evaluated for each vessel and the resultant relief loads calculated.

Reflux failure: In distillation systems, failure of the reflux pump causes the vapour from the column overhead to flow to the condenser without returning any reflux to the column. Column pressure rises as the vapour load builds up with reduced condensation capacity. This is often the governing scenario for distillation column pressure relief, particularly for columns with high vapour traffic and limited condenser capacity.

Set Pressure Selection: MAWP, Accumulation, and Back Pressure

Set pressure is the gauge pressure at which the relief valve is set to begin opening. For a spring-loaded direct-acting PRV, this is the pressure at which the process force on the disc equals the spring force (the “set pressure” is defined at which the valve reaches 10% lift, not at first pop). The set pressure is stamped on the valve nameplate and must match the vessel’s maximum allowable working pressure (MAWP) exactly — not the normal operating pressure, not the design pressure, but the MAWP.

The MAWP is the maximum gauge pressure permissible at the top of the vessel at the coincident temperature for the service designation. It is determined by the vessel design code (ASME Section VIII Division 1 or 2, PD 5500, EN 13445) based on the material, wall thickness, and construction details of the vessel, and it is stamped on the vessel nameplate by the vessel manufacturer.

Accumulation is the increase in vessel pressure above the set pressure during actual relieving. ASME Section VIII permits a maximum accumulation of 10% above MAWP for a single relief valve in a non-fire case, and 21% above MAWP for a fire case. This means that for a vessel with MAWP 10 barg, the single non-fire relief valve may set at 10 barg and the vessel pressure may rise to 11 barg (10% accumulation) before the valve is providing full rated capacity. The valve must be sized to relieve the design relieving load at 11 barg — not at 10 barg. This is the accumulation allowance and it is frequently misunderstood.

Back pressure is the pressure at the relief valve outlet (from the relief header system, the flare header pressure, or atmospheric pressure for open vents). Back pressure affects both the set pressure performance and the valve capacity. For conventional spring-loaded PRVs, back pressure above approximately 10% of set pressure causes the effective set pressure to increase (superimposed back pressure) and reduces valve capacity. Balanced bellows or pilot-operated PRVs can accommodate much higher back pressure — up to 30–50% of set pressure for balanced bellows, and effectively unlimited for pilot-operated valves — without set pressure shift or significant capacity reduction.

Sizing Calculations: Gas, Liquid, and Steam Service

The API 520 sizing equation for gas and vapour service (the most common PRV sizing case) is:

A = W / (C × Kd × P1 × Kb × Kc) × √(T × Z / M)

Where: A = required orifice area (mm² or in²); W = required relieving capacity (kg/h or lb/h); C = gas constant function of the specific heat ratio (k = Cp/Cv), derived from tables in API 520; Kd = effective discharge coefficient (0.975 for a certified PRV with API 520 Annex D rating, or the manufacturer’s published value); P1 = absolute relieving pressure (MAWP × 1.1 for single valve non-fire case) (kPa or psia); Kb = back pressure correction factor; Kc = combination correction factor for installations with a rupture disc upstream; T = relieving temperature (K or °R); Z = compressibility factor; M = molecular weight of the gas.

The equivalent liquid service sizing equation:

A = Q / (Kd × Kw × Kc × Kv) × √(G / (P1 – P2))

Where: Q = required relieving capacity (L/min or US gpm); Kw = correction factor for overpressure other than 25% (for liquid service only); Kv = viscosity correction factor; G = specific gravity of liquid relative to water at 15°C; P1 = inlet relieving pressure; P2 = back pressure.

For saturated steam service, a simplified steam sizing equation is available in API 520 that is more practical for steam PRV sizing than the general gas equation, and provides higher accuracy for steam conditions because it incorporates steam properties directly rather than requiring the user to calculate Z and M for steam.

Two-Phase Relieving: The Sizing Complication

Two-phase flow through relief valves — mixtures of liquid and vapour that occur when liquid flashes as pressure drops through the valve, or when the process stream is already two-phase — is one of the most technically complex areas of PRV sizing and one of the most consequential if handled incorrectly.

API 520 Part I (current edition) provides guidance on two-phase PRV sizing using the Omega method (a simplified approach developed specifically for PRV sizing) and reference to ASME Section VIII appendix 11 for the full methodology. The Omega parameter characterises the flashing tendency of the fluid (the degree to which it flashes from liquid to vapour as pressure drops from inlet to outlet conditions through the valve) and is calculated from the fluid thermodynamic properties at the relieving conditions.

The critical error in two-phase PRV sizing is applying the vapour-phase sizing equation to a two-phase case. The vapour equation assumes that the entire relieving mass flow is gaseous, which dramatically overestimates the volumetric flow for a given mass flow (liquid is much denser than vapour). The result is a calculated orifice area that is much smaller than required — the valve will be grossly undersized. For services where significant flashing occurs (LPG, light naphtha, LP steam condensate), applying the correct two-phase sizing methodology is critical.

Selecting the Valve: Spring-Loaded, Pilot-Operated, and Rupture Disc

Once the required orifice area is determined, the next step is selecting the valve type and the standard orifice size from the API 526 standard orifice table.

Conventional spring-loaded PRVs are the standard choice for the majority of pressure vessel relief applications. They are simple, reliable, self-contained, and well-understood. Their limitations are sensitivity to back pressure (limited to approximately 10% of set pressure for back pressure without capacity or set pressure impact) and sensitivity to inlet pressure drop — API 520 requires that the pressure drop in the inlet piping to the PRV must not exceed 3% of set pressure (to prevent chatter caused by the pressure at the valve inlet dropping below re-seating pressure when the valve is open).

Balanced bellows PRVs use a flexible metal bellows connected between the disc and the bonnet to compensate for back pressure effects on the disc, allowing operation with variable back pressure up to approximately 30–40% of set pressure without set pressure shift or significant capacity reduction. They are used on compressor interstage relief, on relief valves discharging to common elevated pressure headers, and on any service where variable back pressure would be problematic for a conventional PRV.

Pilot-operated PRVs use a separate pilot valve (which is a small, accurately set pressure relief device) to sense system pressure and control the opening and closing of the main valve. They provide superior performance for high back-pressure applications, for services requiring very tight blowdown (rapid re-seating after the overpressure condition resolves), and for large-orifice applications where the spring force required to set a conventional PRV would be impractically large. Pilot-operated PRVs are the standard choice for gas transmission pipeline relief, for large compressor station relief, and for any application requiring a very large orifice (letter T or larger in the API 526 table).

Rupture discs are non-reclosing pressure relief devices — they fail (burst) at a specified pressure, opening a full-bore path to the relief system. They are used in combination with spring-loaded PRVs (rupture disc upstream of PRV to prevent PRV fouling and seat leakage in corrosive service), as the sole relief device for extremely toxic or corrosive services where PRV seat leakage cannot be tolerated, and as a supplementary relief device for fire cases on large vessels where the PRV cannot be sized large enough to provide the required relief capacity. When a rupture disc is installed upstream of a PRV, the combination correction factor Kc = 0.9 must be applied to the PRV sizing equation to account for the restriction of the rupture disc device.

Installation and Common Mistakes

API 520 Part II provides detailed installation requirements that directly affect PRV performance. The most frequently violated requirements in practice are:

Inlet pipe pressure drop exceeding 3% of set pressure: Long or undersized inlet lines create excessive pressure drop when the PRV is relieving, causing the inlet pressure at the PRV to drop below the re-seating pressure while the relieving event is still ongoing, causing the valve to chatter. The solution is inlet pipe sizing to limit pressure drop to ≤3% of set pressure at full rated flow.

Discharge pipe back pressure exceeding the allowable for the valve type: Conventional PRV discharging to a common elevated-pressure flare header without accounting for the imposed back pressure. The solution is to use a balanced bellows or pilot-operated PRV where back pressure is significant.

Isolation valve under the PRV not locked open: A block valve installed under a PRV for maintenance isolation must be locked open and tagged in a management-of-change controlled system. An inadvertently closed isolation valve removes the PRV from service, leaving the protected vessel without overpressure protection. ASME VIII requires a positive means of ensuring the isolation valve is locked open when the PRV is in service.

Summary

Pressure relief valve sizing is a combination of rigorous contingency analysis (API 521) and precise calculation (API 520). Get the contingency analysis right first — identify every credible overpressure scenario, calculate the relieving load for each, and size for the worst case. Then apply the correct API 520 sizing equation for the fluid phase and service conditions, select the correct valve type for the back pressure and service requirements, and install per API 520 Part II. Set the pressure at the MAWP, understand the accumulation allowance, and never accept a relief valve without seeing the sizing calculation that demonstrates it is adequate for the governing contingency. This is engineering that protects lives — it deserves the rigour the standards demand.