Verified product catalogue
Choose a product
4 products match
AWV-000213
Stainless Steel Gate Valve – Flanged PN16
Stainless Steel · PN16 · PN16
Price: On Application
AWV-000381
Forged Stainless Steel Gate Valve – Screwed BSPT
Stainless Steel · BSPT · Class 800
Price: On Application
AWV-000580
Stainless Steel Gate Valve – Flanged ANSI 150
Stainless Steel · ANSI 150 · ANSI 150
Price: On Application
Technical overview and selection guidance
A gate moves linearly out of the flow path for isolation. These valves are generally selected for fully open or fully closed duty rather than routine throttling. Stainless steel grade and product construction must be matched to chloride level, temperature and fabrication requirements; “stainless” is not a universal corrosion guarantee.
Where Stainless Steel Gate Valves fit
Stainless Steel Gate Valves may be considered where its operating principle, envelope and materials suit the process. Confirm whether the duty is isolation, throttling, diversion, non-return or pressure control; a familiar valve type is not automatically the lowest-risk choice.
Selection checklist
| Factor | What to confirm |
|---|---|
| Process medium | Composition, concentration, solids, viscosity, toxicity and cleaning regime. |
| Pressure and temperature | Normal, design, transient and vacuum conditions against the manufacturer curve. |
| Materials | Body, trim, seat, seals, fasteners and coatings—not body material alone. |
| Connections | Nominal size, bore, flange or thread standard, face-to-face and installation space. |
| Operation | Manual or actuated, cycle rate, closing time, fail action, feedback and utilities. |
| Compliance | Project specification, testing, water, fire-safe or hazardous-area requirements. |
Common specification mistakes
- Quoting only nominal size and pressure class.
- Assuming a material name proves chemical compatibility.
- Ignoring transient pressure, differential pressure or installation orientation.
- Selecting an actuator from running torque alone.
- Treating an approval held by one product variant as applying to the whole range.
Frequently asked questions
Can one pressure rating be applied to every Stainless Steel Gate Valves?
No. The allowable pressure changes with materials, temperature, design, size and the governing standard. Use the current product pressure-temperature table.
What information is needed for automation?
At minimum: valve make and model, size, differential pressure, measured or published torque/thrust, supply, cycle time, fail action, control signal and environment.