Verified product catalogue
Choose a product
12 products match
AWV-000159
Cast Iron Gate Valve – Flanged PN16 – Stainless Steel Stem – PN16 Rated
Cast Iron · PN16 · PN16, PN10
Price: On Application
AWV-000261
Cast Iron Gate Valve – Flanged PN16 – Brass Stem – PN10 Rated
Cast Iron · PN16 · PN16, PN10
Price: On Application
AWV-000372
Cast Iron Gate Valve – Flanged PN16 – Cast Brass Seat
Cast Iron · PN16 · PN16
Price: On Application
AWV-000390
Cast Iron Gate Valve – Flanged Table D
Cast Iron · Table D · 6.9 Bar
Price: On Application
AWV-000495
Cast Iron Vacuum Tanker Gate Valve – Heavy Pattern – Hydraulic Ram Spring Jack
Cast Iron · AGRI Standard Square · 1.5 Bar
Price: On Application
AWV-000528
Cast Iron Gate Valve – Flanged PN16 – Cast Bronze Seat – Mounting Flange
Cast Iron · PN16 · PN16, PN10
Price: On Application
AWV-000529
Cast Iron Gate Valve – Flanged PN16 – Cast Bronze Seat – Proximity Sensor
Cast Iron · PN16 · PN16, PN10
Price: On Application
AWV-000530
Cast Iron Gate Valve – Flanged PN16 – Cast Bronze Seat – Position Indicator
Cast Iron · PN16 · PN16, PN10
Price: On Application
AWV-000531
Cast Iron Gate Valve – Flanged PN16 – Quick Closing
Cast Iron · PN16 · PN16, PN10
Price: On Application
AWV-000614
Cast Iron Gate Valve – Flanged PN16 – Rising Stem
Cast Iron · PN16 · PN16, PN10
Price: On Application
AWV-000615
Cast Iron Gate Valve – Flanged ANSI 150
Cast Iron · ANSI 150 · ANSI 150, PN10, PN16
Price: On Application
Technical overview and selection guidance
A gate moves linearly out of the flow path for isolation. These valves are generally selected for fully open or fully closed duty rather than routine throttling.
Where Cast Iron Gate Valves fit
Cast Iron Gate Valves may be considered where its operating principle, envelope and materials suit the process. Confirm whether the duty is isolation, throttling, diversion, non-return or pressure control; a familiar valve type is not automatically the lowest-risk choice.
Selection checklist
| Factor | What to confirm |
|---|---|
| Process medium | Composition, concentration, solids, viscosity, toxicity and cleaning regime. |
| Pressure and temperature | Normal, design, transient and vacuum conditions against the manufacturer curve. |
| Materials | Body, trim, seat, seals, fasteners and coatings—not body material alone. |
| Connections | Nominal size, bore, flange or thread standard, face-to-face and installation space. |
| Operation | Manual or actuated, cycle rate, closing time, fail action, feedback and utilities. |
| Compliance | Project specification, testing, water, fire-safe or hazardous-area requirements. |
Common specification mistakes
- Quoting only nominal size and pressure class.
- Assuming a material name proves chemical compatibility.
- Ignoring transient pressure, differential pressure or installation orientation.
- Selecting an actuator from running torque alone.
- Treating an approval held by one product variant as applying to the whole range.
Frequently asked questions
Can one pressure rating be applied to every Cast Iron Gate Valves?
No. The allowable pressure changes with materials, temperature, design, size and the governing standard. Use the current product pressure-temperature table.
What information is needed for automation?
At minimum: valve make and model, size, differential pressure, measured or published torque/thrust, supply, cycle time, fail action, control signal and environment.