Valve specification is an art as much as a science — and getting it wrong is expensive in ways that go far beyond the cost of the valve itself. An incorrectly specified valve might be discovered at factory acceptance testing, at piping installation, or — worst of all — at commissioning when the process is running and the valve fails to perform. Developing rigorous valve specification skills means understanding the full chain from process conditions to delivered product, knowing which parameters are critical and which are standard, and communicating requirements unambiguously to suppliers. This guide covers the complete valve specification process from first principles.
- A complete valve data sheet must specify not just the design conditions but also the operating conditions, upset conditions, and minimum/maximum flow conditions — a valve specified only for design conditions is specified for a single point that may not represent the most demanding actual service condition
- The piping class (sometimes called the P&ID line class or piping material specification) is the primary specification tool in piping engineering, and all valve specifications must reference and be consistent with the applicable piping class
- Tag-specific valve data sheets are essential for critical valves — a valve scheduled as “1 off globe valve, 2-inch, Class 300” without flow conditions, pressure drops, and fluid data cannot be verified for correct sizing, trim selection, or actuator sizing
The Valve Data Sheet: Your Specification Contract
The valve data sheet is the technical document that communicates everything a supplier needs to manufacture, test, and certify the correct valve for a specific application. A well-constructed data sheet is unambiguous, complete, and verifiable — it leaves no room for the supplier to make assumptions that might result in a non-conforming product. A poorly constructed data sheet, or the absence of one, is an invitation for surprises.
Industry-standard data sheet formats are available from instrument and valve societies (ISA, VDMA, BVAA) and from most major project engineering companies. These formats provide a framework that ensures no critical parameter is omitted. However, the value of a standard format is only realised when every field is correctly filled in — a data sheet with blank fields, “TBD” entries, or placeholder values is not a specification.
For control valves, the data sheet format defined in ISA-75.07 (formerly ISA S20) and the equivalent IEC 60534-7 provides the comprehensive parameter list required for control valve specification. For on-off and isolation valves, project-specific data sheet formats derived from these standards and supplemented with project-specific requirements are standard practice.
Process Conditions: What to Include and Why
The starting point for every valve specification is the process conditions. These must be specified completely, accurately, and for all relevant operating scenarios — not just the design point.
Fluid composition: Specify the fluid completely, not just by a generic name. “Crude oil” is not sufficient — specify the API gravity, water cut, H2S content, CO2 content, wax content, and any other components relevant to material selection. “Natural gas” needs the full gas analysis including H2S, CO2, water dewpoint, and any heavy components. “Process water” needs pH, dissolved solids, chloride content, and temperature. The fluid composition determines material compatibility, lubrication requirements, and in some cases the flow calculation (phase behaviour, density variation).
Pressure conditions: Specify maximum allowable working pressure (MAWP), design pressure, normal operating pressure, minimum operating pressure, and hydrostatic test pressure (if different from standard). For valves that experience pressure differentials (control valves, regulators), specify the differential pressure at maximum flow, normal flow, and minimum flow conditions. The maximum differential pressure at minimum flow (often a valve almost fully closed) may be the most severe condition for seat and actuator sizing.
Temperature conditions: Specify design temperature (maximum), normal operating temperature, minimum operating temperature, and start-up temperature. Design temperature drives material selection and flange class. Minimum temperature drives toughness requirements and whether any special low-temperature material testing is needed. Start-up temperature is sometimes far lower than normal operating temperature (cold start, cryogenic purge) and may impose additional requirements.
Flow conditions: For isolation valves, specify maximum and minimum flow velocities (to verify trim and body sizing is appropriate). For control valves, specify maximum flow, normal flow, and minimum controllable flow — with the corresponding inlet pressure and outlet pressure at each condition. These three conditions determine the required Cv range and valve sizing. Including only the design flow point without turndown requirements is a specification error that will result in a valve that cannot control at low flow.
Piping Class and Its Relationship to Valve Specification
The piping class (piping material specification) is the master specification document that defines the materials, pressure-temperature ratings, flange standards, testing requirements, and valve types approved for use in each service category on a plant. A well-developed piping class system means that individual valve specifications can reference a piping class designation and have most of the design parameters predefined.
A typical piping class designation might be “1A1” meaning: pressure class 150 (1), carbon steel (A), normal process service (1). A more aggressive service might be “3C2” meaning: pressure class 300 (3), 316 stainless steel (C), H2S service (2). The piping class document for each designation specifies the acceptable pipe materials, fittings, flanges, gaskets, bolting, and valve types. Any valve specified for a given line must be consistent with the piping class.
This system has enormous practical advantages: it reduces the specification burden on individual valve data sheets (the piping class covers many material parameters), it ensures consistency across the plant (all valves in a given service use the same material system), and it makes procurement management much simpler (all Class 150 carbon steel valves across the plant can be procured against the same piping class specification).
The limitation of piping class specifications is that they define the minimum requirements for a generic service category. Safety-critical valves, control valves, and valves in unusual service conditions need tag-specific data sheets that supplement the piping class requirements with service-specific parameters. Never rely on the piping class alone for critical valve specifications.
Specifying End Connections
End connection specification seems straightforward but is a frequent source of errors that cause delays at installation. The complete end connection specification requires: connection type (flanged, butt-weld, socket-weld, threaded, wafer, lug), standard (ASME B16.5, EN 1092-1, API 6D, etc.), pressure class or PN rating, flange facing (raised face, flat face, ring type joint), nominal bore (NPS or DN), and for wafer and lug valves, the flange standard the valve is designed to bolt between.
For welded end connections (butt-weld and socket-weld), also specify: the weld end preparation (ASME B16.25 for butt-weld preparations), the pipe schedule or wall thickness to which the valve end is matched (ensures the bore and weld bevel match the connecting pipe), and the material composition of the weld ends (for dissimilar metal welds or when post-weld heat treatment is required).
The face-to-face dimension must be specified for any valve that is replacing an existing valve or where the space between piping flanges is fixed by design. For globe and gate valves, ASME B16.10 or API 6D defines standard face-to-face dimensions. For butterfly and ball valves, face-to-face dimensions vary significantly between manufacturers and must be either explicitly specified or verified against the available spool length.
Trim and Material Specification
Trim specification — the internal wetted components including seats, plug, disc, gate, ball, and stem — must be complete and unambiguous. The minimum trim specification includes: seat material and hardness (e.g., 13Cr stainless overlaid with Stellite 6 for erosive service, or PTFE for clean low-temperature service), plug/disc/gate material, stem material, and any special surface treatments.
For leakage class specification, reference ANSI/FCI 70-2 leakage classes (Class I through Class VI) explicitly rather than using vague terms like “tight shutoff” or “bubble-tight.” Class IV (0.01% of rated Cv) is appropriate for most metal-seated valves in general service. Class VI (zero bubble leakage) is required for soft-seated valves in applications where any leakage is unacceptable. Specifying “Class VI” for a metal-seated gate valve in steam service is an unachievable requirement — metal-seated gate valves reliably achieve Class II-III, not Class VI. Mismatched leakage class requirements cause significant difficulty at factory acceptance testing.
Body cavity fill material (for cavity-filled valves like double-block-and-bleed ball valves) must be specified where relevant. The body cavity fill may be required to be compatible with the process fluid, non-toxic, and suitable for the service temperature range.
Actuator and Controls Specification
Actuated valve specifications need an additional section covering the actuator and control instrument requirements. The key parameters are: actuator type (pneumatic spring-return, hydraulic, electric), fail-safe position (FC, FO, or FL), supply medium and pressure (instrument air at 4-7 bar, hydraulic fluid at XX bar), control signal (4-20mA, 24VDC on-off, HART, Fieldbus), explosion protection classification (ATEX Zone 1 or Zone 2, IECEx, CSA Class I Division 1 or 2), minimum and maximum operating temperature for actuator, and enclosure rating (IP65, IP67, NEMA 4X).
For control valves with positioners, also specify: positioner type (basic pneumatic, digital HART, Foundation Fieldbus, PROFIBUS PA), digital communication protocol details (if applicable), any required diagnostic capabilities (valve signature testing, PST for ESD), and any specific features required (split-range operation, local position indicator, limit switches, manual override).
Actuator sizing requirements should be stated explicitly. The minimum requirement is: “Actuator shall be sized for the maximum required breakaway torque/thrust with a safety factor of X at minimum instrument air supply pressure of Y bar.” For ESD valves, also specify the maximum closing time at minimum supply pressure and verify that the actuator sizing calculation confirming this will be included in the supplier’s documentation package.
Testing and Inspection Requirements
Testing requirements must be specified explicitly because the default tests in API 598 or EN 12266-1 are the minimum and may not be sufficient for the application. Any additional tests — fire testing, fugitive emissions testing, low-temperature testing, PMI, Charpy impact tests, ferrite testing — must be explicitly called out in the purchase specification or data sheet.
Inspection requirements should specify: whether factory acceptance testing (FAT) is required, who will witness (client, third-party inspector, or manufacturer self-certification), which tests will be witnessed versus reviewed on reports only, the required notice period for FAT invitation, and the disposition of non-conformances (hold-inspect-reject-waiver process).
For valves purchased as SIL-rated final elements, the specification must also reference the applicable SIL certificate and safety manual requirements, and confirm that the supplier will provide all documentation required for integration into the SIL verification package.
Documentation Requirements
The documentation deliverables required from the valve supplier should be specified in the purchase order or data sheet. Standard documentation requirements include: data sheets (as-built, confirming all specified parameters), CMTRs for all pressure-containing materials, test reports (including shell test, seat leakage test, and any additional tests), dimensional drawings for dimensional verification, installation and maintenance manuals, and spare parts list with recommended spare quantities for 2-year operation.
For SIL-rated valves, add: safety manual per IEC 61508/61511 requirements, failure rate data with reference to the FMEDA (Failure Mode Effects and Diagnostic Analysis) from the SIL certification, and proof test procedure. For fugitive emissions-compliant valves, add: ISO 15848 or API 624 test certificate for the specific valve design and packing configuration.
Valve specification is a discipline that rewards those who understand both the process engineering context and the valve engineering detail. A specification written by someone who understands why each parameter matters is far more effective than one filled out mechanically from a template. Invest the time to understand each parameter you specify — and always ask yourself: “If this field is wrong or missing, what goes wrong with the delivered valve?”