UK industrial valve sourcing, automation packages and practical application support

ALLWAY VALVESIndustrial valve supply & selection Request a Quote

Technical article

How to Read a Valve Datasheet: The Engineer’s Complete Guide

Expert guide to reading and interrogating a valve datasheet — understanding every field, identifying errors and omissions, and using datasheets to drive correct procurement and inspection.

  • A valve datasheet is the primary technical procurement document for any industrial valve — it defines every parameter the manufacturer needs to supply the correct valve, and every field left blank, incorrectly completed, or vaguely specified is a potential source of a wrong valve, a procurement dispute, or a valve that fails in service.
  • The ability to read, interrogate, and critically review a valve datasheet is one of the most practically valuable skills in process and mechanical engineering — separating engineers who specify valves confidently from those who rely on vendors to fill in the gaps and hope for the best.
  • Common datasheet errors — leaving actuator details unspecified, confusing design and operating conditions, failing to state leakage class, and omitting flange face type and gasket specification — are entirely preventable with a systematic review approach that this guide covers step by step.

I review a lot of valve datasheets. Some are models of clarity — every field completed, every ambiguity resolved, the valve’s service conditions fully defined, the technical requirements unambiguous. Most are not. The average project datasheet I see has at least five fields that are either blank, contradictory, or so vague they give the supplier three different valid interpretations. Each one of those fields is a potential procurement problem, inspection dispute, or in-service failure. Here’s how to read and write datasheets properly.

Header Information: Identity and Traceability

The header of the datasheet establishes the document’s identity and traceability: project name and number, document number, revision number and date, tag number (the unique identifier for this valve in the piping system, matching the P&ID), and the applicable piping class or valve specification number. These fields seem administrative but are critical — a datasheet with no revision control is a document that can’t be formally issued, reviewed, or approved, and a valve with no tag number can’t be tracked through procurement, inspection, and installation.

Check that the tag number on the datasheet matches the P&ID. Check that the valve type called up on the datasheet matches what’s shown on the P&ID (e.g., the P&ID shows a ball valve but the datasheet calls up a butterfly valve — surprisingly common). Check that the piping class reference on the datasheet is consistent with the line specification shown on the P&ID.

Service Conditions: The Technical Core

The service conditions section defines the fluid, pressure, and temperature that the valve must handle. This section is more nuanced than it appears:

Fluid description — “natural gas” is not adequate. Specify the composition (methane %, CO2 %, H2S %, heavier hydrocarbons), molecular weight, specific gravity, and any special properties (toxic, corrosive, carcinogenic). The fluid description drives material selection, seal compatibility, fire safe requirements, and NACE compliance.

Operating vs design conditions — both must be stated. Normal operating pressure and temperature are the typical service conditions. Design pressure and temperature are the maximum allowable conditions, including all credible upset scenarios. The valve pressure class must accommodate the design conditions, not just operating conditions. A valve on a system with a relief valve set at 150% of normal operating pressure must be rated for 150% of normal, not just normal. This is where the most common pressure class errors occur.

Minimum temperature — often omitted from datasheets for valves in warm climate applications. But if the system will be depressurised in winter, or if the fluid is liquefied gas that could flash to low temperatures, the minimum temperature drives material selection (austenitic stainless vs carbon steel impact testing requirements). Never leave minimum temperature blank.

Valve Body Specification

Valve type and standard — specify both the type (ball, gate, butterfly, globe, check) and the applicable design standard (API 6D, ASME B16.34, EN 13709). The standard defines dimensional requirements, pressure ratings, and testing that the manufacturer must comply with.

Size and pressure class — nominal pipe size (NPS or DN) and ASME pressure class or PN rating. Confirm these are consistent with the piping class for the line the valve is installed in. A Class 150 valve in a Class 300 piping class is a non-compliance that will be caught at inspection — but better caught at datasheet review.

End connections — flange standard (ASME B16.5), face type (RF, RTJ, FF), and dimensional facing standard. Omitting face type means the supplier can deliver either raised face or ring joint flanges — and if the adjacent pipe flanges are RTJ, a raised face valve won’t connect without modification.

Face-to-face dimensions — specify the governing standard (ASME B16.10 for most flanged steel valves) and any specific dimension requirements if the valve is replacing an existing valve in a fixed installation.

Materials Section

Every pressure-containing and pressure-controlling component must have its material specified explicitly. The minimum list: body, bonnet/cover, stem, closure element (ball, gate, disc, plug), seats, stem seals/packing, body-to-bonnet gasket, and bolting. Generic descriptions (“stainless steel,” “suitable material”) are not adequate — specify the ASTM grade: A182 F316L, A351 CF8M, A276 Type 316L. For sour service, add “NACE MR0175/ISO 15156 compliant” and specify the maximum hardness requirement.

Testing and Certification Fields

The testing section defines what the manufacturer must test and what documentation must be provided. Check that: pressure test type (hydrostatic or pneumatic) and acceptance standard are stated; seat leakage class is explicitly specified (API 6D Rate A, or ISO 5208 Rate A for zero leakage — “minimum leakage” means different things to different manufacturers); fire safe certification standard is stated if required (API 607, API 6FA, ISO 10497); and anti-static test requirement is included for quarter-turn soft-seated valves in hydrocarbon service.

The documentation section should list every document required in the MDR — material certificates (EN 10204 certificate type), dimensional records, test reports, fire safe certificate, NACE certificate. Make this list explicit; anything not listed will not be supplied without a formal correspondence request after delivery.

Reading datasheets critically is a learned skill that improves with every review. Develop the habit of checking every field — not just the ones that look important. The blank field for minimum temperature, the missing face type, the unstated leakage class — these are the ones that generate expensive non-conformance reports three months into a procurement cycle. Five minutes of careful datasheet review at the start saves five weeks of problem resolution at the end.