UK industrial valve sourcing, automation packages and practical application support

ALLWAY VALVESIndustrial valve supply & selection Request a Quote

Technical article

Fugitive Emissions from Valves: ISO 15848, Tightness Classes and Low-Emission Packing Systems

  • Fugitive emissions from valve stem packing are a major source of VOC and methane releases in process plants — ISO 15848-1 and ISO 15848-2 provide the testing and qualification framework that drives low-emission valve design.
  • The tightness classification system in ISO 15848 — Class A, B, and C — defines the maximum allowable leakage rate per unit of packing length and temperature cycle, and selecting the right class for your application determines whether your plant meets EPA Method 21, EU IED, and operator-specific emissions targets.
  • Modern low-emission packing systems using expanded graphite, PTFE-encapsulated rings, and live-loaded spring assemblies can achieve and maintain Class A performance over thousands of thermal cycles — but only if specified, installed, and maintained correctly.

Why Valve Fugitive Emissions Matter More Than Ever

If you’re responsible for a process plant that handles hydrocarbons, solvents, or any volatile organic compounds, your valve packing is leaking. Not catastrophically — not in a way you’d notice with your eyes or nose on a routine walkdown — but it’s leaking. Every valve stem packing in your plant is a potential fugitive emission source, and over an entire plant with thousands of valves, those small leaks add up to significant environmental and financial impact.

Fugitive emissions regulations have tightened dramatically in recent years. The US EPA’s equipment leak regulations under 40 CFR Part 63 LDAR (Leak Detection and Repair) programmes, the European Union’s Industrial Emissions Directive (IED), and increasingly stringent national regulations in major industrial economies have all pushed the acceptable emission threshold down — and the monitoring frequency up. For new plant design, specifying low-emission valves is now not just good practice but a regulatory requirement in many jurisdictions.

The financial case is equally compelling. A valve leaking at 500 ppm of methane — comfortably within what might once have been considered acceptable — represents a real loss of product to atmosphere. In a plant with several thousand valves, even a small average leak rate across the fleet translates to significant annual product loss. Getting on top of fugitive emissions is both an environmental obligation and a profit centre.

ISO 15848-1: Type Testing for Valve Packing Systems

ISO 15848-1 defines the type testing procedure for qualifying valve packing assemblies for low fugitive emission service. Type testing means testing a specific valve and packing combination to demonstrate that it can meet a defined leakage standard over a defined number of mechanical and thermal cycles. A valve design that passes ISO 15848-1 type testing can then be specified with confidence for applications requiring that leakage class.

The test procedure involves mounting the valve with its packing in a test rig, applying helium at the rated test pressure, and measuring the leakage rate across the packing seal while cycling the valve through its full operating range. The cycling sequence includes a defined number of mechanical cycles (stem strokes) and thermal cycles (heating to maximum rated temperature and cooling back to ambient). The measured leakage rate, normalised per unit length of packing and stem diameter, determines the tightness class achieved.

The number of cycles required for each class is substantial: Class A testing requires 2,500 mechanical cycles; Class B requires 1,500 cycles; Class C requires 500 cycles. These numbers are not arbitrary — they represent representative service life scenarios for different types of valves. A control valve that cycles continuously in a process loop will accumulate thousands of stem cycles per year; an isolation gate valve on a pipeline might complete only a handful of cycles annually.

The Tightness Classification System

ISO 15848-1 defines three tightness classes based on the maximum allowable leakage rate per millimetre of stem diameter and per metre of packing length. The leakage is measured in mg/s of the test medium (helium), which allows direct comparison between different valve and packing sizes.

Class A is the most stringent class, with a maximum leakage rate of 1×10⁻⁶ mg/(s·mm) at test pressure and temperature. This is the class required for the most demanding applications — toxic service, high-VOC content hydrocarbons, and applications where any detectable emission is unacceptable. In terms of field measurement using Method 21 (organic vapour analyser screening), Class A performance typically corresponds to readings below 50–100 ppm at the stem seal.

Class B allows maximum leakage of 1×10⁻⁴ mg/(s·mm) — two orders of magnitude more than Class A. This is suitable for many general process applications with flammable or moderately toxic fluids where regulatory requirements mandate low emission performance but the strictest Class A specification is not required. Class B performance typically corresponds to field readings below 500 ppm.

Class C permits up to 1×10⁻² mg/(s·mm) — the least stringent of the three. It’s primarily applicable to non-hazardous services or where simple low-emission performance is required as a step above conventional packing. The corresponding field detection threshold is approximately 10,000 ppm, which is the EPA’s typical action level for LDAR programmes.

ISO 15848-2: Production Testing

While ISO 15848-1 covers type testing of the valve and packing design, ISO 15848-2 covers production testing — the acceptance testing of individual valves as they leave the manufacturing facility. Type testing proves the design; production testing proves that each individual valve has been correctly assembled to that design.

ISO 15848-2 production testing uses a simplified procedure compared to the full type test. Each valve is subjected to a defined number of mechanical cycles and a leak test at test pressure. The acceptance criterion is that the measured leakage rate must not exceed the class value demonstrated in the type test. For Class A valves, this means testing at a level of detail that requires sensitive helium leak detection equipment — conventional water or soap tests are not adequate for confirming Class A performance.

The practical implication is that specifying ISO 15848-2 production testing adds cost and time to valve manufacture. Not all valve manufacturers have the test equipment required for Class A production testing, which effectively limits your supply chain to manufacturers who have made the investment in low-emission valve production. This is worth verifying during the procurement process — a valve with a Class A type test certificate but without production testing may not deliver Class A performance in every unit delivered.

Low-Emission Packing Technologies

Conventional braided packing — typically graphite-based or PTFE-based rings compressed into the stuffing box by a gland follower — achieves adequate sealing for most standard applications but struggles to maintain consistent low-emission performance over extended service. The fundamental issue is relaxation: the packing compresses under the initial bolt load, but over time — through thermal cycling, pressure cycling, and mechanical vibration — the packing consolidates and the effective sealing stress reduces.

Modern low-emission packing designs address this through several approaches. Expanded graphite packing rings have exceptional chemical resistance, temperature capability, and conformability to stem and box surfaces. Unlike compressed braided packing, expanded graphite can conform to microscopic surface irregularities, maintaining a continuous seal even as it consolidates. For low-emission applications, a typical arrangement uses a combination of carbon fibre anti-extrusion rings at top and bottom of the packing set, with multiple expanded graphite rings in the middle.

PTFE-encapsulated packing rings provide excellent chemical resistance across virtually the entire pH range and can achieve low-emission performance in moderate-temperature service. PTFE has a relatively high thermal expansion coefficient compared to most metal stems, which must be accounted for in the packing box geometry — a PTFE packing set that’s correctly loaded at ambient temperature may over-stress the stem at elevated temperature as the PTFE expands.

Live loading is the most important feature of a successful low-emission packing system. Live loading means the gland follower is maintained under constant spring force using Belleville (disc spring) washers or helical spring washers around the gland bolts. As the packing consolidates and relaxes, the springs automatically compensate by maintaining the bolt load and packing stress. Without live loading, packing relaxation is a matter of when, not if — typically within the first year of service for a valve that experiences frequent thermal cycling.

EPA Method 21 and LDAR Programme Requirements

The US EPA’s Leak Detection and Repair (LDAR) programme, implemented under various NESHAP (National Emission Standards for Hazardous Air Pollutants) regulations, requires operators to monitor valve stems and other equipment leak sources using organic vapour analysers calibrated to EPA Method 21. The monitoring frequency and repair threshold depend on the specific regulation applicable to the facility, but typical requirements include quarterly monitoring for valves in gas or light liquid service.

When a valve is detected leaking above the threshold (typically 500 ppm or 10,000 ppm depending on the regulation and service), it must be tagged and repaired within a defined timeframe. First repair attempts typically involve adjusting the packing gland; if this doesn’t bring the valve into compliance, the valve must be removed from service and repacked or replaced.

Low-emission valves — those tested and certified to ISO 15848 or equivalent standards — are typically exempt from the most frequent monitoring intervals under LDAR programmes, or are subject to reduced monitoring frequency. The savings in monitoring labour costs for a large plant with thousands of valves can be substantial, and often justify the additional cost of specifying low-emission valves at the design stage rather than retrofitting solutions later.

Specifying Low-Emission Valves: Getting the Details Right

A specification that simply states “low fugitive emission valve” or “ISO 15848 compliant” is incomplete. You need to specify the tightness class (A, B, or C), whether type testing or production testing is required, the number of test cycles, and the applicable temperature range. These parameters must be consistent with the actual service conditions — specifying Class A with 2,500 cycles at 450°C for a valve in ambient temperature water service is over-specification; specifying Class C for a valve in toxic hydrocarbon service at elevated temperature may be under-specification.

The valve end connection and packing box geometry must accommodate the selected packing system. Live loading requires additional stuffing box depth for the spring washers. Some valve designs have packing boxes that are too short to accommodate a proper low-emission packing set, and attempting to install live-loaded packing in a short box results in either inadequate spring travel or inadequate packing length — both of which compromise performance.

Maintenance procedures for low-emission packing differ from conventional packing practice. Periodically checking and adjusting the live load spring compression — using the torque and gap measurements specified by the manufacturer — is required to maintain performance over the valve’s service life. Operators who re-pack a low-emission valve with conventional packing during a maintenance shutdown have effectively destroyed the valve’s certified performance, and the valve will need to be re-tested if emissions compliance is to be maintained.