What information should I provide for a valve quotation?
Provide media, size, quantity, connection, design and operating pressure, temperature, materials, operating method, fail action and any approval or testing requirements. Attach the line or equipment specification where possible.
Can a valve be selected from pipe size and pressure class alone?
No. These do not establish chemical compatibility, temperature capability, differential pressure, flow behaviour, solids tolerance, leakage requirement or actuation demand.
Does “fail closed” always mean spring-to-close?
No. Fail position describes the required process outcome after loss of the relevant utility or signal. Valve action, actuator spring direction and control arrangement must be considered together.
Are calculator results a final valve size?
No. The tools provide transparent preliminary calculations. Final sizing requires the correct standard or manufacturer method and complete process data.